Hydrogen again
By the start of work with liquid hydrogen for the Energia launch vehicle, scientific and technical support for this line had been provided by 1977. A production facility for liquid hydrogen with a capacity of up to 10 thousand t per year had been created. A fleet of rail tank cars with screen-vacuum insulation for transporting liquid hydrogen had been built. Test stands for hydrogen-fuelled engines with thrust of 50 t at Zagorsk and 300 t at Nizhnyaya Salda had been constructed. Work had practically begun on developing two liquid-propellant hydrogen engines with thrust of 7.5 t (chief designer V.F. Bogomolov) and 40 t (chief designer A.M. Lyulka). A cryogenic machine-building complex was created (director of the Institute of Cryogenic Technology V.P. Belyakov). A number of studies were carried out on materials science under cryogenic temperatures and on the effect of liquid hydrogen on structural metals at the Physico-Technical Institute, the Central Scientific Research Institute of Materials Science and the State Institute of Applied Chemistry. The explosive properties of systems (hydrogen and oxygen in various combinations) were studied by physical state (gas, liquid and solid). The work was carried out by the Institutes of Chemical Physics of the Academy of Sciences and of Applied Chemistry. In 1976 a flying laboratory based on the Tu-154 aircraft with an NK-88 engine was developed; the first flights were carried out somewhat later. The NK-88 engine had a thrust of 29 t and a service life of up to 50 h. However, consumption of liquid hydrogen did not grow to the declared level. At the end of the 1970s the government decided to halt the construction and design of the production bases "Kuybyshevazot", "Navoiazot" and the one in the city of Salda.
In the United States, after the completion of the Apollo program, production of liquid hydrogen had fallen and, at the start of work on the Space Shuttle, amounted to 70 thousand t per year.
By 1980, liquid hydrogen production was operating in the USSR at Chirchik, Zagorsk and Dneprodzerzhinsk, but at full load. At Chirchik and Zagorsk, plants were in operation that used gaseous hydrogen obtained by electrolysis of water. At Navoi and other nitrogen-industry complexes, plants were in operation that used a hydrogen-nitrogen mixture drawn off from ammonia synthesis units.
The wide introduction of hydrogen fuel was held back, for example in aviation, by the need for a more confident solution of the problems of operating hydrogen systems and of ground servicing. The cost of liquid hydrogen in 1980 was 5.6 roubles per kilogram. After ten years of operation of the plants at their design load, it was planned to reach a cost of 2.5 roubles per kilogram of hydrogen.
In the search for cheaper production, the prospective use of plasma-chemical and thermoelectrochemical methods of producing hydrogen was considered. The possibility of using nuclear energy in electrolysis and thermochemical decomposition processes was studied. NIKIET and the Kurchatov Institute showed that radioactive units that had served their time could be used for cheap splitting of water. Solid hydrogen in the form of snow was obtained by throttling a hydrogen-helium mixture and by throttling the liquid into a vacuum.
The German division of Airbus states the following. Over the last hundred years the population of the Earth has grown rapidly. Energy consumption has increased. Until now the sources of energy have been coal, oil, natural gas and wood. When they are burned, carbon dioxide is produced, which accumulates in the atmosphere. Questions arise: how long will fossil raw materials last, and how long can the greenhouse effect on Earth continue to be created? Industrially developed oil reserves will last for another 40 years; further extraction is linked to rising costs. Aviation, although it consumes less than 3% of the energy resources extracted, requires radical solutions that do not depend on the situation developing with fuels.
Firms led by the German company "Deutsche Aerospace Airbus", with the main partners being the A.N. Tupolev design bureau and the N.D. Kuznetsov engine bureau, are carrying out joint work on a transport aircraft running on hydrogen fuel, the "Cryoplane". The first generation of liquid-hydrogen aircraft will be built on the basis of the traditional types of A-300B Airbus. The main problem in accommodating liquid hydrogen is its volume, four times greater than that of kerosene, and its extremely low temperature, which requires special design measures. The advantage of liquid hydrogen is that its weight, compared with kerosene, is three times smaller, which reduces the mass of the aircraft.
In Russia, liquid hydrogen was regarded as the fuel of the future. The path to it lies through an intermediate stage: natural gas. The A.N. Tupolev design bureau is expanding work on projects for an aircraft running on liquefied natural gas, the Tu-156. The cryogenic complex at the airport consists of an electrolyzer for producing liquid hydrogen from water or a converter for producing it from natural gas, treatment facilities, and a liquefaction unit. To reduce the cost of producing the complexes, serial manufacture and installation at airports is envisaged. Small airports will receive transportable modules.
On safety. Yes, a certain psychological barrier exists. But petrol engines, too, once aroused fear. A hydrogen tank for an automobile was tested on a high-speed trolley, simulating the destruction or instantaneous depressurization of the tank; the hydrogen also escaped almost instantly, and there was never an explosion. From 1978, for almost ten years, two cars, an RAF and a "Volga", running on hydrogen ran in Moscow. The harmlessness of the exhaust, even with a petrol-hydrogen mixture, rises sharply owing to more complete combustion of the petrol.
When creating the Energia launch vehicle, in order to improve its mass characteristics, the task was set of supplying the rocket with supercooled propellant components and of maintaining the specified temperatures while it stood on the launch complex.
In solving this task, the limited capacity of the power supply systems of the launch complex was taken into account. Therefore, in creating the ground refueling systems, preference was given to those methods of supercooling the components that are characterized by minimum energy consumption and that also ensure long-term storage of the components without any change in their condition.
To improve the mass characteristics of the rocket by increasing the density of the propellant components loaded, for the first time in domestic rocket technology the task of fueling the launch vehicle in large quantities with supercooled hydrogen and oxygen was successfully solved. The United States used so-called boiling hydrogen. Supercooled oxygen had been used for a long time, since the R-9.
The hydrogen refueling system that was created ensured the supply to the rocket, in refueling mode, of supercooled liquid hydrogen (down to -255 °C), and the maintenance of its temperature there at the level of -253 °C in thermostatting mode at the final stage of preparing the rocket for launch.
Alongside the main task of supercooling the components, a number of interrelated tasks were solved, including ensuring the purity of the cryogenic components and the drying of the RG-1 fuel.
The systems created for fueling Energia have no analogues in domestic or world technology and are unique examples of refueling systems.
The cryogenic refueling systems for liquid oxygen and liquid hydrogen were developed and manufactured by post box A-3605; the RG-1 fuel refueling system was made by the "Zhdanovtyazhmash" production association, to technical specifications from KBOM, on the basis of initial data from NPO Energia.
To cool cryogenic liquids below their boiling point, that is, to obtain supercooled liquids, various refrigeration processes are used, which can be carried out in three ways:
- by means of a heat exchanger using a refrigerant at the required temperature level (refrigeration machines, heat exchangers with cryogenic liquids boiling at a temperature lower than that of the liquid being cooled);
- by bubbling a non-condensing gas through it;
- by direct vacuum pumping of the liquid bath.
In the method of cooling cryogenic liquids by means of refrigeration machines, the type of refrigeration machine is chosen. Two types are used at present. The first covers refrigeration installations implementing a low-temperature cycle in the classic set of units: a compressor, a cooler, an expansion machine, and a cooler or heat exchanger to remove the thermal load. The second is refrigeration machines with internal heat regeneration. In such machines the regenerator heat exchanger is located in the dead space of the expansion machine, and the expansion process proceeds simultaneously with the heat exchange process in the regenerator. Heat regeneration takes place simultaneously with the compression of the working medium. The cooling of cryogenic liquids in gas refrigeration machines takes place in the heat exchanger by means of the cooling effect of expanding the working gas, with the performance of external work.
The method of cooling cryogenic liquids by means of refrigeration machines is used, as a rule, in cases where it is necessary to exclude losses of the liquid being cooled during its cooling and long-term storage. When storing large quantities of cryogenic liquids, the use of this method requires the installation of bulky and expensive machines, which is not economically justified.
Refrigeration machines with internal heat regeneration are compact and relatively simple to operate, and they can easily be automated, but they have a small refrigerating capacity and can be used for cooling and thermostatting only small quantities of cryogenic liquids.
The method of cooling by means of a heat exchanger is equally applicable to the cooling of any cryogenic liquid. As the refrigerant, a liquid boiling at a temperature lower than that of the liquid being cooled may be used, or a gas cooled to the required temperature level by means of a separate refrigeration cycle.
As refrigerants for supercooling hydrogen, liquid hydrogen boiling under vacuum may be used. For cooling liquid oxygen, liquid nitrogen may be used, as well as liquid nitrogen boiling under vacuum, a binary mixture (liquid oxygen plus liquid nitrogen under vacuum), and liquid hydrogen. The method of cooling a liquid by bubbling through it a non-condensing gas, for example helium, consists in the following: the helium bubbles, passing through the mass of the liquid, become saturated with the vapor of the liquid up to an equilibrium state. The liquid carrying the helium bubbles lowers its temperature, since vaporization takes place at the expense of the internal energy of the liquid. This method is distinguished by its reliability and high refrigerating capacity. Its drawback is the large consumption of expensive and scarce helium during cooling. For this, a large stock of helium in cylinders must be held at the launch position, as well as a complex system for cleaning the cooled liquid of impurities. This reduces the effectiveness of the method.
In the method of cooling a liquid by evacuating the vapor space, cooling is carried out by partial evaporation of the liquid with continuous removal of the vapor by a vacuum unit. Vacuum pumping is a simple, reliable method that requires only suitable means for pumping out the vapor. Such a method can be used for supercooling liquid hydrogen, but it is poorly suited to deep cooling of liquid oxygen, owing to the low saturated vapor pressure of oxygen at these temperatures. Vacuum units give a very low capacity at such an inlet pressure.
One of the most acceptable means of evacuation, despite its low efficiency, is an installation with a gas ejector. The advantages of such an installation are simplicity, reliability in operation, and the possibility of removing large quantities of heat from the liquid being cooled.
For cooling high-boiling liquids, however, refrigeration machines are used. The appropriate type of machine is chosen depending on the degree of cooling.
The method of cooling liquid oxygen for fueling Energia, using a gas ejector, is simple to operate at minimum cost, requires no regulation and, owing to the absence of machine equipment, has maximum reliability. In addition, its implementation does not require the creation of a special nitrogen storage facility. To ensure autonomy, the cooling system includes two coolers, which cool the oxygen going to fueling of the second-stage unit and of the first-stage units separately to the required temperature. The total consumption of liquid nitrogen per refueling is 200 t.
The principle of operation of the supercooling system is as follows: in the cooler on the supply line to the second-stage unit, the oxygen is cooled by heat exchange with nitrogen boiling at atmospheric pressure to a temperature of -195 °C, after which it goes to fueling the unit. In the cooler on the fueling line of the first-stage units, the oxygen is cooled to the same temperature and then mixed with the flow of liquid oxygen arriving through the bypass line, as a result of which it warms to a temperature of -190 °C and enters the fueling of the first-stage units. The temperature of the liquid oxygen at the outlet of the cooler of the first-stage units is set in advance and is achieved by redistributing the flows between the cooler and the bypass line by means of appropriate valves.
In connection with the need to supercool oxygen, the task of ensuring the purity of the product was also solved. An analysis of the possible methods of cooling liquid hydrogen showed that the most expedient is to cool the fueling flow in a heat exchanger placed in a bath of liquid hydrogen boiling under vacuum. Accordingly, the use of various types of vacuum pumping means in the liquid hydrogen cooling system was analyzed. The following main requirements imposed on the system were taken into account:
- a definite refrigerating capacity at a given boiling temperature in the cooler bath;
- explosion safety;
- economic efficiency;
- simplicity of control and operation;
- specified reliability indicators.
The value of the refrigerating capacity, and the pressure level and temperature of the gas being pumped out, determine the volumetric capacity of the vacuum pumping means and therefore their type and number. Pumping out hydrogen vapors heated to normal temperatures is provided by the most high-capacity means: axial and centrifugal vacuum pumps and ejectors. However, "warm" pumping requires a large amount of machine equipment to meet the requirements placed on the system, as well as considerable energy consumption for heating the gas, which, combined with high power consumption, makes it inefficient and complicates the system owing to the need for special heat-exchange apparatus and for a supply of heat-transfer medium. For this reason, the variant of the hydrogen cooling system with pumping out of heated vapors was rejected. These shortcomings are largely eliminated when "cold" vapors are pumped out. However, despite the fairly wide range of vacuum pumps produced by domestic industry, their choice for cooling systems for cryogenic liquids is limited. The main reason is the lack of reliable, high-capacity pumps capable of operating at cryogenic temperatures. Given the state of vacuum technology in the 1980s, the most mastered means of pumping out "cold" hydrogen vapors were gas ejectors, in which nitrogen is used as the active gas. Thus the scheme and the composition of the equipment for the hydrogen cooling system were determined.
It was decided to cool the liquid hydrogen supplied to the rocket in tubular heat exchangers of two coolers arranged in series. The refrigerant is liquid hydrogen boiling in the shell space of the heat exchanger at reduced pressure. The hydrogen vapors from the vapor space of the coolers are pumped out by ejectors. The pneumatic-hydraulic scheme makes it possible to provide different refrigerating capacities of the system by bringing different numbers of ejectors into operation.
The coolers are horizontal, fully welded, cylindrical double-walled vessels with heat exchangers built into the inner vessel (the cooler bath). A capillary-porous coating is applied to the outer surface of the tubes, which serves to intensify heat exchange. Heat exchange takes place between the flow of liquid hydrogen moving through the tubes of the heat exchanger and the hydrogen boiling in the shell space at a pressure below atmospheric.
The results of work with bench models and the first flight Energia launch vehicles confirmed the correctness of the technical solutions adopted in the ground refueling systems for the task of supercooling the propellant components: liquid oxygen, during refueling, in a bath of liquid nitrogen boiling at atmospheric pressure; liquid hydrogen, during refueling, in a bath of liquid hydrogen boiling at reduced pressure; RG-1 fuel, by means of refrigeration machines. The ground systems provided refueling of the rocket at the specified temperatures with a high degree of accuracy. The chosen schemes for supercooling the components ensured the fulfillment of the task with minimum energy expenditure. Supercooling the cryogenic components during refueling, without preliminary chilling in storage tanks, substantially increased the reliability of the refueling systems, shortened the time needed to prepare the systems for work with the rocket, and made possible long-term storage with a guarantee of the components' condition. At the same time, the questions of ensuring the required purity of the components were also solved.
The schemes adopted in the refueling systems for supercooling large quantities of propellant components, through heat exchange among the various cryogenic products, are distinguished by minimum energy consumption, which made it possible to solve the task without building additional large refrigeration centers and powerful power supply systems for the test stand and launch site at the range. In creating the cryogenic systems, the problem was also solved of organizing, at the range, workplaces (stands) for assembling large spherical tanks with a volume of 1430 m³ and delivering them to the installation site. Welding the tanks required a workplace protected from the external environment and maintaining a stable positive temperature inside. This task was solved by temporarily using one of the bays of the rocket's assembly and test building, and by setting up workplaces enclosed by large inflatable tents on the test stand and at the launch site itself, when the assembly and test building had to be vacated because of the installation there of equipment for assembling the launch vehicle.
Original version of the text
Опять водород
К началу работ с жидким водородом в плане создания ракеты-носителя "Энергия" к I977 г. было осуществлено научно-техническое обеспечение этого направления. Было создано производство жидкого водорода с мощностью до 10 тыс. т в год. Создан парк железнодорожных цистерн с экранно-вакуумной изоляцией для перевозки жидкого водорода. Построены испытательные стенды для двигателей с жидким водородом на тягу 50 т в Загорске и 300 т в Нижней Салде. Практически начата отработка двух жидкостных двигателей на водороде с тягой 7,5 т (главный конструктор В.Ф.Богомолов) и 40 т (главный конструктор А.М.Люлька). Создан криогенно-машиностроительный комплекс (директор Института криогенной техники В.П.Беляков). Проведен ряд работ по материаловедению в условиях криогенных температур и воздействия жидкого водорода на конструкционные металлы в Физико-техническом институте, Центральном НИИ материаловедения и Государственном институте прикладной химии. Изучены взрывчатые свойства систем (водород и кислород в различных сочетаниях) по физическому состоянию (газ, жидкость и твердое тело). Работы проводили институты химической физики Академии наук и прикладной химии. В 1976 г. разработана летающая лаборатория на самолете Ту-154 с двигателем НК-88, первые полеты проводились несколько позднее. Двигатель НК-88 имел тягу 29 т и ресурс до 50 ч. Однако потребление жидкого водорода не вырастало до заявленного уровня. Правительством было принято решение в конце семидесятых годов о прекращении строительства и проектирования производственных баз "Куйбышевазот", "Навоиазот" и в городе Салда.
В Соединенных Штатах после завершения программы "Аполлон" производство жидкого водорода упало и составляло на начало работ с "Спейс Шаттлом" 70 тыс. т в год.
К 1980 г. функционировало производство жидкого водорода в СССР в Чирчике, Загорске и Днепродзержинске, но с полной загрузкой. В Чирчике и Загорске действовали установки, использующие газообразный водород, получаемый электролизом воды. В Навои и других комбинатах азотной промышленности действовали установки, использующие водородно-азотную смесь, отбираемую из агрегатов синтеза аммиака.
Широкое внедрение водородного топлива сдерживалось, например, в авиации, из-за необходимости более уверенного решение вопроса эксплуатации водородных систем и наземного обслуживания Стоимость жидкого водорода в 1980 г. была 5,6 руб. за килограмм. После десятилетней эксплуатации установок при проектной их загрузке планировалось достичь стоимости 2,5 руб. за килограмм водорода.
В поисках удешевления производства рассматривалось в перспективе применение плазмохимического и термоэлектрохимического методов получения водорода. Изучалась возможность применения ядерной энергии в процессах электролиза, термохимического разложения. НИКИЭТ и институт имени Курчатова показали, что могут быть использованы отработавшие свой срок радиоактивные агрегаты для дешевого расщепления воды. Получение твердого водорода в виде снега осуществлялось дросселированием водородно-гелиевой смеси и дросселированием жидкости в вакуум.
Немецкое отделение "Эрбас" утверждает следующее. За последние сто лет население Земли стремительно выросло. Повысилось потребление энергии. До сих пор источниками энергии были: уголь, нефть, природный газ, древесина. При их сгорании образуется углекислый газ, накапливающийся в атмосфере. Возникают вопросы: надолго ли хватит ископаемого сырья и как долго еще можно создавать парниковый эффект на Земле. Промышленно разрабатываемых резервов нефти хватит еще на 40 лет, дальнейшая добыча связана с повышением затрат. Авиация, хотя и потребляет менее, чем 3 % добываемых энергоресурсов, требует кардинальных решений, не зависящих от ситуации, складывающейся с топливами.
Фирмы под руководством немецкой компании "Deutche Aerospace Airbus" с основными партнерами - КБ А.Н.Туполева и двигательным бюро Н.Д.Кузнецова - ведут совместные работа по созданию транспортного самолета на водородном топливе "Криоплан". Первое поколение самолетов на жидком водороде будет создаваться на базе традиционных типов аэробусов А-300В. Генеральная проблема при размещении жидкого водорода - это в 4 раза больший объем по сравнению с керосином, и экстремально низкая температура, которая требует специальных конструктивных мер. Преимущество жидкого водорода - меньший втрое, по сравнению с керосином, вес, что снижает массу самолета.
В России жидкий водород рассматривался как топливо будущего. Путь к этому - через промежуточный этап - природный газ. В КБ А.Н.Туполева расширяются работы над проектами самолета на сжиженном природном газе - Ту-156. Криогенный комплекс в аэропорту состоит из электролизера для производства жидкого водорода из воды или конвертера для производства из природного газа, очистных сооружений, устройства для сжижения. Для снижения стоимости производства комплексов задумано серийное их изготовление и монтаж в аэропортах. Маленькие аэропорты будут получать транспортируемые модули.
О безопасности. Да, существует определенный психологический барьер. Но ведь и бензиновые двигатели когда-то вызывали страх. Автомобильный водородный бачок испытывали на скоростной тележке, имитируя разрушение или мгновенную разгерметизацию бака - водород также почти мгновенно улетучивался, а взрыва не было ни разу. По Москве с 1978 г. почти десять лет ходили два автомобиля, РАФ и "Волга", работавшие на водороде. Безвредность выхлопа даже на бензоводородной смеси резко повышается за счет более полного сгорания бензина.
При создании ракеты-носителя "Энергия" в целях улучшения ее массовых характеристик была поставлена задача обеспечения ракеты переохлаждаемыми компонентами топлива и поддержания заданных температур при стоянке ее на стартовом комплексе.
При решении этой задачи учитывались ограниченные мощности систем энергоснабжения стартового комплекса. Поэтому при создании наземных систем заправки предпочтение отдавалось тем способам переохлаждения компонентов, которые характеризуются минимальными энергозатратами, а также обеспечивают длительное хранение компонентов без изменения их кондиции.
Для улучшения массовых характеристик ракеты путем повышения плотности заправляемых компонентов топлива впервые в отечественной ракетной технике задача заправки ракеты-носителя в больших количествах переохлажденными водородом и кислородом была успешно решена. Соединенные Штаты использовали так называемый кипящий водород. Переохлажденный кислород применялся давно - с Р-9.
Созданная система заправки водородом обеспечивала подачу в ракету в режиме заправки переохлажденного (до -255 ╟С) жидкого водорода и поддержание его температуры там на уровне -253 ╟С в режиме термостатирования на заключительном этапе подготовки ракеты к пуску.
Наряду с основной задачей переохлаждения компонентов был решен ряд взаимосвязанных с этим задач, в том числе по обеспечению чистоты криогенных компонентов, осушке горючего РГ-1.
Созданные для заправки "Энергии" системы не имеют аналогов в отечественной и мировой технике и являются уникальными образцами заправочных систем.
Криогенные системы заправки жидким кислородом и жидким водородом были разработаны и изготовлены предприятием п/я А-3605, система заправки горючим РГ-1 - предприятием ПО "Ждановтяжмаш" по техническим заданиям КБОМ на основе исходных данных НПО "Энергия".
Для охлаждения криогенных жидкостей ниже температуры кипения, то есть получения переохлажденные жидкостей, применяются различные холодильные процессы, которые можно осуществить тремя способами:
- посредством теплообменника с использованием хладагента на требуемом температурном уровне (холодильные машины, теплообменники с криогенными жидкостями, кипящими при температуре, более низкой, чем охлаждаемая);
- барботированием неконденсирующимся газом;
- прямым вакуумированием ванны с жидкостью.
В способе охлаждения криогенных жидкостей с помощью холодильных машин производится выбор типа холодильных машин. В настоящее время применяются два их типа. Первый охватывает холодильные установки, реализующие низкотемпературный цикл в классической совокупности агрегатов: компрессор, холодильник, расширительная машина, охладитель или теплообменник для снятия тепловой нагрузки. Второй - это холодильные машины с внутренней регенерацией тепла. В таких машинах теплообменник регенератор расположен в мертвом пространстве расширительной машины, процесс расширения протекает одновременно с процессом теплообмена в регенераторе. Регенерация тепла осуществляется одновременно с процессом сжатия рабочего тела. Охлаждение криогенных жидкостей в газовых холодильных машинах происходит в теплообменнике за счет эффекта охлаждения - расширения рабочего газа с совершением внешней работы.
Метод охлаждения криогенных жидкостей с помощью холодильных машин применяется, как правило, в случаях, когда необходимо исключить потери охлаждаемой жидкости в процессе ее охлаждения и длительного хранения. При хранении больших количеств криогенных жидкостей применение этого способа требует установки громоздких и дорогостоящих машин, что экономически не оправдано.
Холодильные машины с внутренней регенерацией тепла компактны и относительно просты в эксплуатации, они легко могут быть автоматизированы, но имеют небольшую холодопроизводительность и могут применяться для охлаждения и термостатирования только небольших количеств криогенных жидкостей.
Способ охлаждения посредством теплообменника в одинаковой мере применим для охлаждения любой криогенной жидкости. В качестве хладагента может использоваться жидкость, кипящая при температуре более низкой, чем охлаждаемая, или газ, охлаждаемый до требуемого температурного уровня с помощью постороннего холодильного цикла.
В качестве хладагентов для переохлаждения водорода может быть использован жидкий водород, кипящий под вакуумом. Для охлаждения жидкого кислорода могут использоваться жидкий азот и жидкий азот, кипящий под вакуумом, бинарная смесь (жидкий кислород плюс жидкий азот под вакуумом) и жидкий водород. Способ охлаждения жидкости путем барботажа через нее неконденсирующегося газа, например, гелия, заключается в том, что пузырьки гелия, проходя через массу жидкости, насыщаются парами жидкости до равновесного состояния. Несущая пузырьки гелия жидкость понижает свою температуру, так как парообразование идет за счет внутренней энергии жидкости. Этот метод отличается надежностью и высокой холодопроизводительностью. Недостатком его является большой расход дорогостоящего и дефицитного гелия в процессе охлаждения. Для этого на стартовой позиции необходимо иметь большой запас гелия в баллонах, а также сложную систему очистки от примесей охлаждаемой жидкости. Это снижает эффективность данного метода.
В способе охлаждения жидкости путем вакуумирования парового пространства охлаждение производится за счет частичного испарения жидкости при непрерывном отводе паров вакуумным агрегатом. Вакуумирование является простым, надежным способом, требующим только наличия соответствующих средств откачки пара. Такой способ может быть использован для переохлаждения жидкого водорода, однако он мало пригоден для глубокого охлаждения жидкого кислорода вследствие малого давления насыщенных паров кислорода при этих температурах. Вакуумные агрегаты дают очень малую производительность при таком давлении на входе.
Одним из наиболее приемлемых средств вакуумирования, несмотря на низкий коэффициент полезного действия, является установка с газовым эжектором. Преимуществами такой установки является простота, надежность в работе и возможность отвода от охлаждаемой жидкости больших количеств тепла.
Для охлаждения же высококипящих жидкостей применяются холодильные машины. В зависимости от степени охлаждения выбирается соответствующий тип машин.
Способ охлаждения жидкого кислорода для заправки "Энергии" с применением газового эжектора при минимальной стоимости прост в управлении, не требует регулирования и в связи с отсутствием машинного оборудования обладает максимальной надежностью. Кроме того, для его реализации не требуется создания специального хранилища азота. Для обеспечения автономности система охлаждения включает в себя два охладителя, которые обеспечивают охлаждение до требуемой температуры кислорода, идущего на заправку отдельно блока второй ступени и блоков первой ступени. Суммарный расход жидкого азота на одну заправку составляет 200 т.
Принцип работы системы переохлаждения заключается в следующем: в охладителе, стоящем на линии подачи в блок второй ступени, кислород за счет теплообмена с кипящим под атмосферным давлением азотом охлаждается до температуры -195 ╟С, после чего идет на заправку блока. В охладителе, стоящем на линии заправки блоков первой ступени, кислород охлаждается до такой же температуры, а затем смешивается с потоком жидкого кислорода, поступающим по байпасной линии, в результате чего нагревается до температуры -190 ╟С и поступает на заправку блоков первой ступени. Температура жидкого кислорода на выходе из охладителя блоков первой ступени задается заранее и достигается за счет перераспределения потоков через охладитель и байпасную линию с помощью соответствующих клапанов.
В связи с необходимостью переохлаждения кислорода была решена задача обеспечения чистоты продукта. Анализ возможных способов охлаждения жидкого водорода показал, что наиболее целесообразным является охлаждение заправочного потока в теплообменнике, размещенном в ванне с жидким водородом, кипящим под вакуумом. В связи с этим анализировалось применение в система охлаждения жидкого водорода различных типов средств вакуумной откачки. При этом учитывались следующие основные требования, предъявляемые к системе:
- определенная холодопроизводительность при заданной температуре кипения в ванне охладителя;
- взрывобезопасность;
- экономическая эффективность;
- простота управления и эксплуатации;
- заданные показатели надежности.
Величина холодопроизводительности, уровень давления и температура откачиваемого газа определяет объемную производительность средств вакуумной откачки, а следовательно, их тип и количество. Откачка подогретых до нормальных температур паров водорода обеспечена наиболее высокопроизводительными средствами: осевыми, центробежными вакуумными насосами и эжекторами. Однако "теплая" откачка требует применения большого количества машинного оборудования для выполнения предъявленных к системе требований, а также значительного расхода энергии на подогрев газа, что в сочетании с большой потребляемой мощностью является неэффективным и усложняет систему из-за необходимости применения специальных теплообменных аппаратов и обеспечения теплоносителем. В связи с этим вариант системы охлаждения водорода с откачкой подогретых паров был отклонен. Указанные недостатки в значительной степени устраняются при откачке "холодных" паров. Однако, несмотря на достаточно большой ассортимент вакуумных насосов, выпускаемых отечественной промышленностью, их выбор для систем охлаждения криогенных жидкостей ограничен. Основной причиной является отсутствие надежных, высокопроизводительных насосов, работоспособных при криогенных температурах. По состоянию развития вакуумной техники на период 80-х годов, наиболее освоенными средствами откачки "холодных" паров водорода явились газовые эжекторы, в которых в качестве активного газа используется азот. Таким образом была определена схема и состав оборудования для системы охлаждения водорода.
Охлаждение подаваемого в ракету жидкого водорода решено было осуществлять в трубчатых теплообменниках двух последовательно расположенных охладителей. Хладагентом является жидкий водород, кипящий в межтрубном пространстве теплообменника при пониженном давлении. Пары водорода из парового пространства охладителей откачиваются эжекторами. Пневмогидравлическая схема позволяет обеспечить различную холодопроизводительность системы за счет включения в работу различного числа эжекторов.
Охладители представляют собой горизонтальные цельносваренные цилиндрические двухстенные аппараты со встроенными во внутренний сосуд (ванна охладителя) теплообменниками. На наружную поверхность трубок нанесено капиллярно-пористое покрытие, которое служит для интенсификации теплообмена. Теплообмен осуществляется между потоком жидкого водорода, движущимся по трубкам теплообменника, и водородом, кипящим в межтрубном пространстве при давлении ниже атмосферного.
Результаты работ со стендовыми образцами и первыми летными ракетами "Энергия" подтвердили правильность принятых в наземных системах заправки технических решений задачи переохлаждения компонентов топлива: жидкого кислорода - в процессе заправки в ванне с жидким азотом, кипящим при атмосферном давлении; жидкого водорода - в процессе заправки в ванне с жидким водородом, кипящим при пониженном давлении; горючего РГ-1 - с помощью холодильных машин. Наземные системы обеспечили заправку ракеты с заданными температурами с высокой степенью точности. Выбранные схемы переохлаждения компонентов обеспечили выполнение поставленной задачи с минимальными энергозатратами. Переохлаждение криогенных компонентов в процессе заправки без предварительного захолаживания в хранилищах существенно увеличило надежность заправочных систем, сократило сроки подготовки систем к работе с ракетой, позволило обеспечить длительное хранение с гарантией кондиционности компонентов. При этом были также решены вопросы обеспечения требуемой чистоты компонентов.
Принятые в заправочных системах схемы переохлаждения больших количеств компонентов топлива за счет теплообмена между собой различных криогенных продуктов отличаются минимальным энергопотреблением, что позволило решить поставленную задачу без создания на полигоне дополнительных крупных холодильных центров и мощных систем энергоснабжения стенда и старта. При создании криогенных систем была также решена проблема организации на полигоне рабочих мест (стендов) для сборки крупногабаритных сферических емкостей объемом 1430 м3 и их доставки к месту монтажа. Для сварки емкостей потребовалось создание рабочего места, защищенного от внешней среды и имеющего внутри стабильную положительную температуру. Эта задача была решена путем временного использования одного из пролетов монтажно-испытательного корпуса ракеты-носителя, а также создания рабочих мест, закрытых надувными палатками большого объема, на самих стенд-старте и старте, когда монтажно-испытательный корпус пришлось освободить в связи с монтажом в нем оборудования для сборки ракеты-носителя.